<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15170</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: remove plate from picker
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
3230/3244 Trendsetter Autoloader:
A plate has been detected on the picker, and must be removed.  This could occur during initialization,
or at the start of a pick command, or "time picker" command.
</text></DescriptionText>
<DescriptionText><text>
For the 3230/3244 Trendsetter Autoloader, this error may occur in the case of an incorrect vaccuum reading.
Use the "picker" command to display the vacuum reading.  It should be around 100 with no plate.  Check the
vacuum threshold level ("set al pvt") to make sure it is above the no-plate level.  Also check the ADC offset
value ("set sat aoff 4") to make sure it is a positive number.
</text></DescriptionText>
<DescriptionText><text>
Platesetter_3244:
This error is reported if the picker vacuum is detected above PVT during initialization.
</text></DescriptionText>
<DescriptionText><text>
Platesetter_3244:
This error is reported if during clearing after an error the picker vacuum is detected
above PVT , or there is still a metal plate detected on the picker or the "plate_loc p
status" is not 0.
</text></DescriptionText>
<DescriptionText><text>
Platesetter_3244:
This error is reported if the "plate_loc p status" is not 0 at the start of a pick.
</text></DescriptionText>
<DescriptionText><text>
Platesetter_3244:
This error is reported if the  "plate_loc p status" is not 0 at the start of an unload.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Trendsetter:
If possible, remove the plate from the picker.  Call the Creo Response Centre for assistance
if necessary.  Select 'Plate Removed' to continue.
</text></DescriptionText>
<DescriptionText><text>
Platesetter_3244:
Lift the bridge and insert support pins,
You may reset the machine if desired of remove the plate from the picker. Selecting 'clear' will
cause the plate to drop (if there really is a plate there).
Resetting the machine will give another opertunity to remove the plate more easily.
Call the Creo Response Centre for assistance if necessary.  Select 'Plate Removed' to continue.
</text></DescriptionText>
</OperatorAction>
<Cause>
3230/3244 Trendsetter Autoloader: There was a plate on the picker when the machine was reset.  The picker
cannot reinitialize itself with a plate on the picker, so the plate must be removed manually.
</Cause>
<Cause>
3230/3244 Trendsetter Autoloader: Incorrect vacuum reading.
</Cause>
<Cause>
3244 Platesetter: During an ale_pick_status_ok check, if the picker plate_loc status is not 0, then
this error is reported.  This check is done before a pick is commenced.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/plate_loc_state_status.xml</LinkAddress><LinkTitle>NVS: plate_loc status</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cal_pvs.xml</LinkAddress><LinkTitle>NVS: al pvs</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cfg_pvt.xml</LinkAddress><LinkTitle>NVS: al pvt</LinkTitle></Link>
<Link><LinkAddress>../nvs/sat_cal_pvt.xml</LinkAddress><LinkTitle>NVS: sat pvt</LinkTitle></Link>
<Link><LinkAddress>../nvs/sat_cal_pvrt.xml</LinkAddress><LinkTitle>NVS: sat pvrt</LinkTitle></Link>
<Link><LinkAddress>../nvs/sat_cal_aoff.xml</LinkAddress><LinkTitle>NVS: sat aoff</LinkTitle></Link>
<Link><LinkAddress>../commands/picker.xml</LinkAddress><LinkTitle>Command: picker</LinkTitle></Link>
<Link><LinkAddress>../commands/Cal.xml</LinkAddress><LinkTitle>Command: Cal</LinkTitle></Link>
<Link><LinkAddress>../error_messages/</LinkAddress><LinkTitle>E_ALE_DROP_PLATE_PICKER</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:54 2008 PST
</Updated>
<Links>
</Links>
</Error>